Indeterminate biliary strictures remain a challenge to accurately diagnose, because they cannot be distinguished as malignant or benign despite initial ERCP and standard sampling methods. Biopsy under direct cholangioscopic vision might be superior to standard ERCP techniques such as brushing or biopsy. The aim of this study was to investigate whether DSOC improves the diagnostic yield in patients with indeterminate biliary strictures, compared with standard ERCP work-up. The primary endpoint was diagnostic accuracy of cholangioscopy or cholangiography at 6 months after the initial ERCP procedure. A total of 61 patients were determined to have an indeterminate biliary stricture based on magnetic resonance cholangiopancreaticography (MRCP) in 3 tertiary referral centres. They were randomised to standard ERCP visualisation with tissue brushing (Control arm) or DSOC visualisation and DSOC-guided biopsy (Study arm). The pathologist was procedure-blinded. Patients in the Control arm underwent an ERCP with cholangiography. A cholangiography-based impression of malignancy (yes/no/indeterminate) was recorded. ERCP-guided brushing was performed with a minimum of 9 passes. Malignancy was determined by cytology or histology on tissue sampling during the index or subsequent ERCP procedure, or surgical specimen histopathology up to 6 months after the index procedure. The assessed stricture was considered benign if malignancy was not confirmed by 6 months after the index procedure. Diagnostic accuracy of only the first procedure was compared between the groups.
The first sample sensitivity of DSOC-guided biopsies was significantly higher than ERCP-guided brushing (68.2% vs 21.4%; P<0.01; see Table). The sensitivity of visualisation (Study arm, 95.5% vs Control arm, 66.7%; P=0.02) and overall accuracy (Study arm, 87.1% vs Control arm, 65.5%; P=0.05) were significantly higher in the Study arm compared with the Control arm, whereas no significant differences were found in specificity, positive predictive value, or negative predictive value. Adverse events were equally low in both arms.
Table. Diagnostic accuracy of ERCP brushing versus DSOC biopsy on first sample [1]
In conclusion, DSOC-guided biopsies are safe and effective with a higher sensitivity compared with standard endoscopic retrograde cholangiopancreatography ERCP techniques for indeterminant biliary strictures.
- Gerges C et al. UEG Week 2019, Abstract LB11.
Posted on
Previous Article
« Global burden of digestive diseases reveals alarming trends Next Article
Half of common medications wreak havoc on gut microbiome »
« Global burden of digestive diseases reveals alarming trends Next Article
Half of common medications wreak havoc on gut microbiome »
Table of Contents: UEGW 2019
Featured articles
Interview with UEG President Prof. Paul Fockens
Upper GI Disorders
Locally active corticosteroid promising in eosinophilic oesophagitis
First-in-human radiofrequency vapor ablation in Barrett’s oesophagus
Irritable Bowel Syndrome
Faecal microbiota transplantation is effective for irritable bowel syndrome
Human milk oligosaccharides improve IBS symptoms
Inflammatory Bowel Disease
Ustekinumab is safe and effective in ulcerative colitis: 2-year data
Decreased microvilli length in CD patients
Phase 2 data shows benefit for mirikizumab in CD patients
Subcutaneous ustekinumab as maintenance therapy in UC
First evidence of long-term efficacy of ABX464 in ulcerative colitis
New treatment may reverse coeliac disease
IBD prevalence 3 times higher than estimated and expected to rise
Microbiome and Microbiota
Early stages of gastric metaplasia: molecular profiling
Plant-based foods and Mediterranean diet associated with healthy gut microbiome
Antibiotic resistance in H. pylori has doubled over last 20 years
Pancreatitis
New model predicts recurrence of acute biliary pancreatitis
Hepatology
Restrictive strategy for cholecystectomy selection does not reduce pain, but does reduce surgery
β-blockers may halt cirrhosis progression: PREDESCI trial
Obeticholic acid prevents liver fibrosis from NASH
Oncology
Metal stents are better than plastic for endoscopic biliary drainage
Ramosetron relieves low anterior resection syndrome
Immunonutrition during neoadjuvant oesophagogastric cancer therapy: no benefit
Endoscopy
EUS-guided histological specimens from the pancreatic cyst wall
Digital single-operator cholangioscopy more sensitive than endoscopic retrograde cholangiopancreatography
New single-use duodenoscope well-liked by endoscopists
Related Articles
October 23, 2019
Ramosetron relieves low anterior resection syndrome
October 23, 2019
First-in-human radiofrequency vapor ablation in Barrett’s oesophagus
© 2024 Medicom Medical Publishers. All rights reserved. Terms and Conditions | Privacy Policy
HEAD OFFICE
Laarderhoogtweg 25
1101 EB Amsterdam
The Netherlands
T: +31 85 4012 560
E: publishers@medicom-publishers.com